Working Principle
This double overcenter valve operates on both directions of a double-acting cylinder, regulating return flow only when pilot pressure is applied. It maintains load stability by locking the actuator in place until commanded otherwise, preventing uncontrolled movement due to external forces or gravity. Each side includes a check valve and a pressure relief circuit, allowing smooth and safe motion control.
This design minimizes hydraulic shocks, enhances equipment safety, and is ideal for systems where load holding and precise control are critical.