Operating principle
The valve contains two independent pressure relief cartridges one for each direction of flow. When pressure in either direction exceeds the pre-set limit, the corresponding cartridge opens and diverts excess oil to the tank (or low-pressure side), preventing system overpressure.
This ensures safe pressure regulation in both directions, regardless of flow direction. The integrated spring-loaded mechanism allows the valve to close quickly after pressure returns to normal, maintaining stable and reliable hydraulic system performance.